Book a service
Refrigerated display cases and drinks fridges in the sales area of a pastry shop
Service

Refrigerated display case maintenance and repair

Cleaning, temperature and airflow checks, fault finding and repair, so your display stays fresh.

Checking the control panel of a display fridge during maintenance

Refrigerated display case maintenance and repair for shops and cafés

A refrigerated display case has to keep the right temperature on every shelf. In glass cases and open multidecks that depends on airflow: if the fans have stopped, the air vents are blocked or the evaporator has iced up, the front row warms up first.

During maintenance we clean the condenser and evaporator, check the fans, airflow, defrost and drain, measure the temperature on the shelves, and inspect the glass, doors, seals and lighting.

How it works

  1. Report

    Send the model of the display case and a description of the problem.

  2. Inspection

    The technician checks the display case on site.

  3. Maintenance or repair

    We carry out the necessary work. The cost depends on the actual working time and the parts and materials used.

  4. Check

    We measure the shelf temperatures before handover.

What we check

01

Airflow

Fans and air vents, so cold air reaches every shelf.

02

Shelf temperature

We measure the temperature of the front and back rows.

03

Condenser and evaporator

Cleaning, so the unit does not have to overwork.

04

Defrost and drain

Evaporator defrost and removal of the defrost water.

05

Glass and doors

Seals, hinges and glass heating.

06

Lighting

LED lighting and illuminated canopy.

07

Refrigerant and compressor

Checking compressor operation and looking for leaks.

08

Electrical parts

Controller, sensors and connections.

Refrigerated display case faults we repair

01

Not holding temperature

Condenser, fan, sensor, thermostat or a refrigerant leak.

02

Front row is warm

Blocked air vents, a fan that has stopped or an iced-up evaporator.

03

Evaporator icing up

A defrost, sensor or airflow fault.

04

Water under the counter

A blocked drain, an overflowing drip tray or excess ice when the defrost is not working correctly.

05

Glass fogging up

A fault in the glass heating or a shop that is too humid.

06

Noise

Fan or compressor wear.

07

Doors, seals and lighting

Repairing sliding glass panels, hinges and seals, and replacing LED strips and power supply units.

08

Will not start or shows an error code

We read the code and check the start relay, thermostat, sensors, controller and electrical connections.

Refrigerated display case repair work

The work starts with finding the fault, which is part of the service work. We keep the most common original spare parts in stock, so a fault can often be fixed on the same visit. With the priority service we reach you within two hours between 9:00 and 17:00 on working days.

  • Replacing the compressor and start components and recharging the system with refrigerant
  • Finding and repairing refrigerant leaks; we only recharge the system once the leak has been fixed
  • Replacing and setting up thermostats, sensors and controllers
  • Replacing evaporator and condenser fans
  • Replacing defrost heaters, defrost timers and defrost sensors

You receive a written summary of the work done, which you can keep with your self-monitoring documents. Materials and spare parts installed by us carry a 12-month warranty, unless the sales documents say otherwise.

We maintain and repair refrigerated display cases and serve-over counters in Tallinn, Harju County and, by arrangement, elsewhere in Estonia. For a more distant site we agree the arrival time separately, and if the round trip is over 40 km, a kilometre fee of €1.24/km is added.

Which refrigerated display cases and multideck display fridges we maintain

Servicing a multideck display fridge in a shop
Servicing a multideck display fridge in a shop

For equipment with a separate condensing unit or on a central system, include the condensing unit details in your report. Fridges and freezers are covered by our fridge and refrigerator repair service.

What to do if the display case starts to warm up

  • Move the most sensitive goods to a fridge or cold room if you can.
  • Check that the unit has power, the fuse has not blown and the air vents are clear.
  • Keep doors and sliding glass panels closed, so the cold lasts longer.
  • Do not turn the temperature down: that will not clear the fault, and more ice may build up on the evaporator.
  • Do not remove ice with a sharp tool, as this can damage the evaporator.
  • If you switch the unit off, wait at least 5 minutes before switching it back on.
  • Check whether one display case is warming up or several, and tell our service team. If several units warm up at once, the cause is often a shared condensing unit or the central system.
  • Write down the temperature and error code, take a photo of the rating plate and call our service line on +372 6729 533.
Measuring the temperature on a display case shelf
Measuring the temperature on a display case shelf

If the display case will be out of action for a longer time, ask about a temporary replacement: we also rent out display cases for the duration of a fault.

Refrigerated display case maintenance and repair prices

The price depends on the call-out, the actual working time and the parts and materials used. Rates are with VAT. The minimum chargeable time is 30 minutes. Prices are valid from 1 July 2025. The price list is not a quote for a specific job. Customers with a maintenance agreement get a lower hourly rate.

01

€43.40

Call-out in Tallinn up to 15 km, working days 9:00 to 17:00

02

€55.80

Call-out up to 20 km and outside the city, working days 9:00 to 17:00

03

€68.20

Labour hour on site, working days 9:00 to 17:00

04

€99.20

Priority service labour hour, on site within 2 hours

What you can do yourself between maintenance visits

  • Only put pre-chilled goods in the display case: it is designed to keep cold goods cold, not to cool warm goods.
  • Do not place goods beyond the edge of the shelf or in front of the air vents.
  • Keep salads and marinated foods covered if you can, because acidic vapours can damage the evaporator.
  • Do not let food scraps get into the defrost drain.
  • If the display case has its own condensing unit, check every 1–3 months whether the condenser is dusty. If the manufacturer’s instructions allow it, disconnect the unit from the mains and remove the dust with a soft brush or a vacuum cleaner.
  • Disconnect the display case from the mains before cleaning, and clean it with a soft cloth and a neutral detergent. Do not use a pressure washer, a water jet, abrasive cleaners or sharp objects.
  • Let us know straight away if the compressor runs for longer than before, the shelf temperature gradually rises or frost forms on the air vents.

You will find exact cleaning instructions in your unit’s user manual.

Frequently asked questions

Why is my refrigerated display case not holding its temperature?

Common causes are a dusty condenser, a fan that has stopped, an iced-up evaporator, air vents covered by goods, a faulty sensor or a refrigerant leak. Temperatures differ between shelves because of stock placement, airflow, fan operation or icing. Note in your report whether the problem affects the whole display case or only one shelf. During maintenance we measure temperatures and check air movement.

Is the temperature on the display the actual temperature of the goods?

No, the display shows the air temperature at the sensor. The reading rises briefly during defrost, which is normal. To check the goods, place a separate thermometer among them in the warmest spot, usually the front row. Write down the readings, because a food business operator must check temperatures regularly so that the cold chain is not broken. If the reading stays high after defrost has finished, call our service line on +372 6729 533.

Do the location of the display case and the climate in the shop affect cooling?

Yes. Many refrigerated display cases are designed for use in a room with an air temperature of up to 25 °C and relative humidity of up to 60%. The rating plate or technical data often carry a code for this, for example 3M2. It means that in climate class 3, at 25 °C and 60% humidity, the unit must keep the goods between -1 and +7 °C. Direct sunlight, a heater or a draught from a door or ventilation makes the compressor work harder, and the goods may warm up.

How quickly can you come?

With the priority service we reach you within two hours between 9:00 and 17:00 on working days. For a more distant site we agree the arrival time separately. A priority service labour hour is €99.20 with VAT. We respond faster to call-outs from customers with a maintenance agreement.

How much does a refrigerated display case repair cost?

On working days 9:00 to 17:00 the call-out is from €43.40 and a labour hour on site is €68.20 with VAT. The price depends on the call-out, the actual working time and the parts and materials used. The rates are in the service price list.

Can maintenance or repair be done when the shop or café is closed?

Yes, by prior arrangement we also come in the evening, at the weekend and at night. Outside normal working hours and on days off the call-out is €80.60 (up to 15 km) or €99.20 (up to 20 km and outside the city) and a labour hour is €99.20. At night, 22:00 to 6:00, and on public holidays the call-out is €130.20 and a labour hour is €124.00. Prices are with VAT.

Is it worth repairing an old refrigerated display case?

If the fault is in the fans, sensors, thermostat or seals, a repair usually pays off. If an older display case needs a new compressor or has a major refrigerant leak, the decision also depends on whether spare parts and a suitable refrigerant can still be obtained. If a repair does not pay off, we say so plainly and help you choose a new or used display case.

How often should a refrigerated display case be serviced?

A technician cleans the condenser and does a general check once or twice a year, more often in a dusty or warm shop. During maintenance we also check the lighting, doors and seals. We report any issues found to the contact person. Additional repairs are separate from maintenance in the scope of work. Whether one can be done depends on the parts needed and the agreed scope of work, and the price depends on the actual working time and the parts and materials used.

Do you also maintain and repair open multideck display fridges, serve-over counters and display cases bought elsewhere?

Yes. Send us the manufacturer, the model and a description of the fault and we will tell you whether we can help and whether spare parts are available. Add a photo of the display case or counter, so that its construction, refrigeration system and the scope of work can be clarified. If it has a separate condensing unit, include that unit’s details too.

How should I prepare a display case or counter for maintenance?

Clear access to the technical components and tell us when the goods can be temporarily removed. Include the manufacturer, model, location, a description of the problem and, if you have them, temperature readings and a photo of how the goods are arranged and of the access to the technical components. Add any lighting, door or seal faults to your request, with photos. Before the visit we clarify the working area and any downtime.

Request maintenance or a repair

Describe what you need and include your contact details. We will get in touch to clarify the next steps.